成人观看视频-成人观看网站a-成人国产mv免费视频-成人国产第一区在线观看-成人国产激情福利久久精品-成人国产精品

服務(wù)熱線:
15821734033
產(chǎn)品展示

您現(xiàn)在的位置:首頁  >  產(chǎn)品展示  >  ELISA試劑盒  >  人ELISA試劑盒  >  人血管內(nèi)皮生長因子(VEGF)Elisa試劑盒說明書

人血管內(nèi)皮生長因子(VEGF)Elisa試劑盒說明書

  • 產(chǎn)品型號:
  • 產(chǎn)品時間:2024-08-10
  • 簡要描述:人血管內(nèi)皮生長因子(VEGF)Elisa試劑盒說明書
    上海慧穎生物科技專業(yè)生產(chǎn)研發(fā)經(jīng)營穩(wěn)定、優(yōu)質(zhì)、高效、實用的ELISA試劑盒,公司提供ELISA試劑盒免費代測,ELISA試劑盒批發(fā)價零售,ELISA試劑盒專業(yè)生產(chǎn)廠家,ELISA試劑盒進口品牌!
  • 產(chǎn)品簡介

人血管內(nèi)皮生長因子(VEGF)Elisa試劑盒說明書

Human Vascular Endothelial cell Growth Factor (VEGF) ELISA Kit

(48Tests)

Store all reagents at 2-8°C Collect sample: serum or blood plasma Assay range 5.0 pg/ml -950 pg/ml


FOR LABORATORY RESEARCH USE ONLY.


NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!


INTENDED USE

This VEGF ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures.The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of VEGF in the sample, this VEGF ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus VEGF concentration. The concentration of VEGF in the samples is then determined by comparing the O.D. of the samples to the standard curve.


PRINCIPLE OF THE ASSAY


The kit assay VEGF level in the sampleuse Purified antibody to coat microtiter


plate wells, make solid-phase antibody, Samples which including standards of known concentrations and unknowns are pipetted into coated microtiter wells, after Incubating ,add Biotinylated anti-IgG,and Combined Streptavidin-HRP, become antibody – antigen - enzyme- antibody complex, after washing Compley, Add TMB substrate solution, TMB Chromogen Solution Becomes blue color At HRP enzyme-catalyzed, And at the effect of acid the color finally become yellow, The intensity of this coloured product is directly proportional to the concentration of VEGF present in the samples. measure the optical densit (OD) at 450 nm with microtiter plate reader, calculate VEGF concentration by standard curve.


REAGENTS PROVIDED


All reagents provided are stored at 2-8° C. Refer to the expiration date on the label.

  1. MICROTITER PLATE 48 wells
  2. Biotinylated anti-IgG 3.0 mL 1 tube

3. STANDARD(800 pg/ml)

0.5ml 1 tube

4. STREPTAVIDIN-HRP

3.0 mL

1 tube

5. STANDARD DILUENT

1.5ml

1 tube

  1. Chromogen Solution A 3.0 mL 1 vial
  2. Chromogen Solution B 3.0 mL 1 vial
  3. STOP SOLUTION 3.0 mL 1 vial


  1. WASH SOLUTION x20 20 mL 1 vial
  2. Instruction 1


SAMPLE COLLECTION AND STORAGE

Serum- Use a serum separator tube(SST) and allow samples to clot for 30minutes before centrifugation for 15minutes at approximay 1000 x g.Remove serum and assay immediay or aliquot and store samples at -20 °C or -80°C.


Plasma - Collect plasma using EDTA or heparin as an anticoagulant.Centrifuge samples for 15 minutes at 1000 x g at 2-8°C within 30minutes of collection.Store samples at -20°C or -80°C.Avoid repeated freeze-thaw cycles.


Cell culture fluid and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20°C or -80°C.Avoid repeated freeze-thaw cycles.


NOTE: Serum, plasma, and cell culture fluid samples to be used within 7 days may be stored at 2-8°C, otherwise samples must stored at -20°C(≤2months) or -80°C(≤6months) to avoid loss of bioactivity and contamination. Avoid freeze-thaw cycles .When performing the assay slowly bring samples to room temperature.


DO NOT USE HEAT-TREATED SPECIMENS.


MATERIALS REQUIRED BUT NOT SUPPLIED


  1. Microplate reader capable of measuring absorbance at 450 nm.


  1. Precision pipettes to deliver 2 ml to 1 ml volumes. .
  2. Adjustable 10ml -100ml pipettes for reagent preparation.
  3. 100 ml and 1 liter graduated cylinders.
  4. Calibrated adjustable precision pipettes, preferably with disposable plastic tips. (A manifold multi-channel pipette is desirable for large assays.)
  5. Absorbent paper.


  1. 37°C incubator.
  2. Distilled or deionized water.
  3. Data analysis and graphing software..
  4. Tubes to prepare standard or sample dilutions.


PRECAUTIONS


  1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.


  1. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.


  1. Do not use kit components beyond their expiration date.


  1. Use only deionized or distilled water to dilute reagents.

5.   Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.

  1. Use fresh disposable pipette tips for each transfer to avoid contamination.


  1. Do not mix acid and sodium hypochlorite solutions.

8.  Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from human blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.

  1. All samples should be disposed of in a manner that will inactivate viruses.


  1. Solid Waste: Autoclave 60 min. at 121°C.

11.  Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.


  1. Substrate Solution is easily contaminated. If bluish prior to use, do not use.


  1. Chromogen Solution B contains 20% acetone, keep this reagent away from sources of heat or flame.


  1. Remove all kit reagents from refrigerator and allow them to reach room


temperature ( 20-25°C).


REAGENT PREPARATION


Standard -The Kit provides a stock standard800 pg/ml. Allow the standard to sit for a minimum of 5 minutes with gentle mixing prior to making dilutions.Pipette 150μL of Standard Dilution into each tube.


(total 5 tubes) Use the 150μL of stock solution to produce a 2-fold dilution series (including 400 pg/ml,200 pg/ml,100 pg/ml,50 pg/ml , 25 pg/ml). Mix each tube thoroughly before the next transfer.


Wash Buffer - If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have compley dissolved. To prepare enough Wash Buffer for one plate, add 20mL Wash Buffer Concentrate into deionized or distilled water to prepare 600mL of Wash Buffer.


ASSAY PROCEDURE


Prepare all Standards before starting assay procedure (see Preparation Reagents). It is recommended that all Standards and Samples be added in duplicate to the Microtiter Plate.


1.       Determine the number of microwell strips required to test the desired number of samples, Each sample, standard and blank should be assayed in duplicate.


  1. add sample: Set blank wells separay (blank comparison wells dont add


sample and ELISA reagent, other each step operation is same). Add 50 μL of Standards or Samples to the appropriate well of the antibody pre-coated Microtiter Plate, and Gently mix. Incubate for 45 min at 37


  1. Configurate liquid: 30 times of wash solution diluted 30 times with distilled water and reserve.
  2. washing: remove Liquid, dry by swing, add washing buffer to every well, still for 30 second then remove, repeat 4 times.


  1. add Biotinylated anti-IgG: Add diluted Biotinylated anti-IgG 50ul to all


wells, Incubate for 30 min at 37


  1. washing:  Operation with 4.


  1. add streptavidin-HRP:  Add streptavidin-HRP 50ul to all wells, Gently mix


Incubate for 15 min at 37


  1. washingOperation with 4.


  1. color: Add Chromogen Solution A 50ul and Chromogen Solution B to each well,Incubate for 15 min at 37


  1. Stop the reaction: Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color Immediay).


  1. assay: take blank well as zero , measure the optical densit (OD) at 450 nm after Adding Stop Solution and within 15min.


CALCULATION OF RESULTS

Average the duplicate readings for each standard,control, and sample and subtract the average zero standard optical density. Construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯數(shù)字),如:三加四=7
上海慧穎生物科技有限公司 版權(quán)所有    備案號:滬ICP備12016933號-2

技術(shù)支持:化工儀器網(wǎng)    管理登陸    網(wǎng)站地圖

聯(lián)系電話:
15821734033

微信服務(wù)號

主站蜘蛛池模板: 天天做天天看夜夜爽毛片 | 成在线人免费视频 | 四虎在线观看视频 | 免费午夜视频 | 午夜啪啪网 | 99久久精品费精品国产一区二区 | 婷婷国产| 亚洲精品一区二区三区在线播放 | 91女神精品系列在线观看66 | 99热久久国产精品免费观看 | 日本人成年视频在线观看 | 99久久精品国产交换 | 久久福利青草精品资源站 | 五月深深爱| 国产精品美女福利视频免费专区 | 午夜免费网站 | 色综久久 | 国产精品久久久久秋霞影视 | 99国产高清久久久久久网站 | 久久99热这里只有精品高清 | 久久这里只有精品99 | 真人毛片 | 日日操夜夜爽 | 国内精品久久久久尤物 | 亚洲精品影院一区二区 | 亚洲一区二区中文字幕 | 免费在线观看中文字幕 | 大学生久久香蕉国产线观看 | 2021久久精品国产99国产 | 国产免费青青青免费视频观看 | 亚洲视频成人 | 欧美日韩在线播放一区二区三区 | 综合激情区视频一区视频二区 | 青草青草久热精品视频99 | 亚洲成a人片在线观看中 | 国产色婷婷精品综合在线 | 成人免费片| 国产l精品国产亚洲区久久 国产nv精品你懂得 国产se98视频精品在这里 | riav久久中文一区二区 | 男女啪啪成人免费网站 | 黄色毛片基地 |